Eaton PowerXL DA1 Communications Manual page 41

Modbus rtu for variable frequency drives/variable speed starters
Hide thumbs Also See for PowerXL DA1:
Table of Contents

Advertisement

DC1
x
x
x
Table 14: Input and output phases
Value
0
1
2
3
4
5
6
7
Table 15: Assigned ratings
Frame
Power
size
Index
FS1
kW
HP
FS2
kW
HP
FS3
kW
HP
FS4
kW
HP
Modbus RTU for variable frequency drive DA1, DC1, DE1 09/16 MN040018EN www.eaton.com
x
(hex) Description
Output index (see table 15)
Input/output phases (see table 14)
Voltage class
0 = 115 V
1 = 230 V
2 = 230 V
3 = 400 V
Frame size (FS)
1 = FS1
2 = FS2
3 = FS3
4 = FS4
Country-specific
Number of phases
default settings
on mains side
kW
3
HP
3
kW
3
HP
3
kW
1
HP
1
kW
1
HP
1
0
1
2
0.37
0.75
0.37
0.5
1
0.5
1.1
0.75
1.5
1.5
1
2
4
5.5
7.5
5
7.5
10
5.5
7.5
11
7.5
10
15
2.6 Operating mode Modbus RTU
Number of phases
on motor side
3
3
1
1
3
3
1
1
3
4
5
0.75
1.5
0.75
1
2
1
2.2
0.75
1.5
3
1
2
11
4
3
15
5
4
11
15
18.5
15
20
25
2 Modbus RTU
6
7
8
1.5
2
2.2
4
3
3
5
4
5.5
7.5
22
30
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerxl dc1Powerxl de1