3
Safety Parameters
3.1

Safety parameter setting method

Use FR Configurator2 to set safety parameters. For details, refer to the FR Configurator2 Instruction Manual.
The operation panel and the parameter unit are not available for reading or writing safety parameters.
 Inverter setup software
Use FR Configurator2 to set safety parameters. Operation must be performed by qualified personnel.
Name
FR Configurator2
 Setting procedure
1.
Safety parameter setting
Refer to the setting method of each parameter and set safety parameters.
Keep the record of the setting values in the customer setting column of the safety parameter list
them before writing safety parameters.
2.
Password setting
Provide password protection for safety parameters to avoid accidental changes.
Passwords must contain one to six alphanumeric characters. Passwords are case-sensitive. (Initial value "000000".)
3.
Safety parameter verification
Read safety parameters and compare the settings with those recorded in the customer setting column of the safety
parameter list
4.
Power reset or inverter reset
Safety parameter settings and the password become effective after the next power-ON or inverter reset.
5.
Operation check of safety sub-functions
Check that safety sub-functions work properly by actually operating the system.
14
3. Safety Parameters
3.1 Safety parameter setting method
Model
SW1DND-FRC2
(page
15) to check that they are correctly set.
Compatible version
1.22Y or later
(page
15) and check