Byte
Bit
1
1
1
2
1
7
3
4
*1
The value "0" or "1" in the parentheses is the bit value.
*2
The signal is used for monitoring. It is not used for controlling the brake.
• STO state
In the STO state, the inverter transfers to "Switching ON inhibited" state.
 Drive Profile Parameters (Acyclic Data Exchange)
 PROFIsafe parameters
PNU
P60022
PROFIdrive PROFIsafe telegram selection
P60044
Fault message counter
P60047
Fault number
• PROFIdrive PROFIsafe telegram selection (P60022)
PNU
Sub
60022
0
PNU
Sub
60022
0
Details of the read values are as follows.
Value
31
Standard telegram 31
• Fault message counter (P60044)
The value of Fault message counter is sent back. This value is incremented when the E.SAF fault occurs.
PNU
Sub
60044
0
PNU
Sub
60044
0
• Fault number (P60047)
Displays up to eight inverter fault detail codes for the faults which occurred after the power is turned ON. (Refer to
the list of fault detail codes.)
While no E.SAF fault occurs, "0" is read for P60047.0 to 7.
PNU
Sub
60047
0 to 7
PNU
Sub
60047
0 to 7
42
6. Safety Communication Functions
6.2 PROFIsafe
Definition of bit
SLS_LIMIT_BIT0_ACTIVE
Bit 0 of selected SLS speed limit value
SLS_LIMIT_BIT1_ACTIVE
Bit 1 of selected SLS speed limit value
SSM
Speed below limit value / Speed equal or above
limit value
SBCS (Device-specific)
Name
Access
Name
R
Tgm selection
Range
Units
0001h to FFFFh
-
Description
Access
Name
R
Fault counter
Range
Units
0000h to FFFFh
-
Access
Name
R
Fault numbers
Range
Units
0000h to FFFFh
-
*2
R/W
Data Type
R
Unsigned16
R
Unsigned16
R
Array [8]
Unsigned16
Data Type
Unsigned16
The selected telegram is sent back.
EEP-ROM
Impossible
-
Data Type
Unsigned16
-
EEP-ROM
Impossible
-
Data Type
Array [8]
-
Unsigned16
EEP-ROM
Impossible
-
Inverter operation
The selected SLS function is shown by the bit value
combination.
[Bit1, Bit0]
[0, 0]: SLS1
[0, 1]: SLS2
[1, 0]: SLS3
[1, 1]: SLS4
OFF (0): The motor speed (output frequency) is
higher than the SSM frequency.
ON (1): The motor speed (output frequency) is
equal to or lower than the SSM frequency.
OFF (1): The brake is operating.
ON (0): The brake is released.
Description
Parameter
Description
Parameter
Description
Parameter
*1
Default
31
Default
0
page 54