Mitsubishi Electric 800 Series Instruction Manual page 6

Functional safety, compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Specifications
Safety sub-function
STO
(IEC/EN 61800-5-2)
(Safe torque off)
SS1
(Safe stop 1)
SLS
(Safely-limited speed)
SSM
(Safe speed monitor)
SBC
(Safe brake control)
Input/output function
Input terminal
Output terminal
Safety parameter setting
*1
Response time
Safety function response time (IEC 61784-3)
*1
Retain the command input for a safety sub-function for a time period equal to or longer than the response time. Otherwise, the intended function
may not be activated.
*2
Refer to details of safety communication functions to set an appropriate timeout time.
6
1. INTRODUCTION
1.1 Compliance with the EU Machinery Directive - Safety sub-functions
Function
Shut-off response time
Deceleration delay time
Monitoring speed
Monitoring speed
Shut-off response time
Number of input terminals
Redundant input mismatch
detection
mismatch permissible time
Filtering time
Number of output terminals
Test pulse off time
Test pulse interval
Description
140 ms or less
0 to 3600 s (parameter setting)
0 to 60 Hz (parameter setting)
0 to 60 Hz (parameter setting)
140 ms or less
1 terminal × 2 channels
0.1 to 2 s (parameter setting)
0.01 to 0.10 s (parameter setting)
1 terminal × 2 channels
2 ms or 4 ms (parameter setting)
1.5 s or less
Password protection for writing
140 ms or less
The response time is the time from when the operation
command is given for a safety sub-function until the function
is activated.
The safety function response time (SFRT) is defined in IEC
61784-3.
When a fault occurs, the response time is calculated as
follows.
SFRT = specified response time + maximum permissible
time for delay in safety communication
*2
+ 60 ms