6.1.3

Safety remote I/O

The FR-E800-SCE inverter supports the following safety remote input and output devices.
 Safety remote output (from the master module to the inverter)
Output signals from the master module are as follows. (Input signals to the inverter)
*1
Device No.
SA¥Yn0
STOC (STO command)
SA¥Yn1
SS1C (SS1 command)
SA¥Yn3
SSMC (SSM command)
SA¥Yn8
SLS1C (SLS1 command)
SA¥Yn9
SLS2C (SLS2 command)
SA¥YnA
SLS3C (SLS3 command)
SA¥YnB
SLS4C (SLS4 command)
*1
"n" indicates a value determined by the station number.
*2
The value "0" or "1" in the parentheses is the bit value.
 Safety remote input (from the inverter to the master module)
Input signals to the master module are as follows. (Output signals from the inverter)
*1
Device No.
SA¥Xn0
STOS (STO output)
SA¥Xn1
SSMS (SSM output)
SA¥Xn8
SLS1S (SLS1 output)
SA¥Xn9
SLS2S (SLS2 output)
SA¥XnA
SLS3S (SLS3 output)
SA¥XnB
SLS4S (SLS4 output)
SA¥XnC
SS1S (SS1 output)
SA¥X(n+1)2
SBCS (SBC monitor output)
*1
"n" indicates a value determined by the station number.
*2
The value "0" or "1" in the parentheses is the bit value.
*3
The signal is used for monitoring. It is not used for controlling the brake.
38
6. Safety Communication Functions
6.1 CC-Link IE TSN safety communication functions
Signal name
OFF (0): STO function enabled.
ON (1): STO function disabled.
OFF (0): SS1 function enabled.
ON (1): SS1 function disabled.
OFF (0): SSM function enabled.
ON (1): SSM function disabled.
OFF (0): SLS1 function enabled.
ON (1): SLS1 function disabled.
OFF (0): SLS2 function enabled.
ON (1): SLS2 function disabled.
OFF (0): SLS3 function enabled.
ON (1): SLS3 function disabled.
OFF (0): SLS4 function enabled.
ON (1): SLS4 function disabled.
Signal name
OFF (1): STO function enabled.
ON (0): STO function disabled.
OFF (0): The motor speed (output frequency) is higher than the SSM frequency.
ON (1): The motor speed (output frequency) is equal to or lower than the SSM
frequency.
OFF (1): SLS1 function enabled.
ON (0): SLS1 function disabled.
OFF (1): SLS2 function enabled.
ON (0): SLS2 function disabled.
OFF (1): SLS3 function enabled.
ON (0): SLS3 function disabled.
OFF (1): SLS4 function enabled.
ON (0): SLS4 function disabled.
OFF (1): SS1 function enabled.
ON (0): SS1 function disabled.
OFF (1): The brake is operating.
*3
ON (0): The brake is released.
*2
Description
*2
Description