Mitsubishi Electric 800 Series Instruction Manual page 37

Functional safety, compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

4.
Set each item on the "Safety Communication Setting" window and click the [OK] button.
Set the Pr.S031 and Pr.S032 setting values as the safety certification code in hexadecimal.
Safety certification code setting example
Set the same value in FR Configurator2 and GX Works3. When the values are inconsistent, connection using safety
communication is not enabled.
GX Works3 setting value
Safety certification code (hexadecimal) : FFFF FFFF
5.
Write unit parameters to the CPU module.
6.
Reset the CPU module.
FR Configurator2 setting value
Pr.S031 (upper) = "65535" (decimal)
Pr.S032 (lower) = "65535" (decimal)
6. Safety Communication Functions
6.1 CC-Link IE TSN safety communication functions
3
4
5
5
5
6
7
8
9
10
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800-sce

Table of Contents