Mitsubishi Electric 800 Series Instruction Manual page 11

Functional safety, compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Wiring
The following describes terminals related to safety sub-functions.
Terminal
Terminal name
symbol
SX1
Safety input (channel 1)
SX2
Safety input (channel 2)
SY1
Safety output (channel 1)
SY2
Safety output (channel 2)
SD
External transistor
common (source (positive
common))
24 VDC power supply
common
PC
Safety input terminal
common
24 VDC power supply
SC1/SC2
Safety output terminal
common
 Terminal layout
 Crimp terminal specifications
2
Wire size (mm
)
0.3
AI 0,34-10TQ
0.5
AI 0,5-10WH
0.75
AI 0,75-10GY
1
AI 1-10RD
1.25/1.5
AI 1,5-10BK
0.75 (for 2 wires)
AI TWIN 2 X 0,75-10GY
*1
Ferrules and the tool are distributed by Phoenix Contact Co., Ltd.
NOTE
• For Ethernet communication wiring, refer to the FR-E800 Instruction Manual (Communication).
• Use PORT1 for connection with the master for PROFIsafe or CIP Safety communication.
Terminal function description
Terminal functions can be selected using Pr.S051 SX1/SX2
terminal function selection. (Refer to
The terminal function can be selected using Pr.S055 SY1/
SY2 terminal function selection. (Refer to
Connect this terminal to the power supply common terminal of
a transistor output (open collector output) device, such as a
programmable controller, in the source logic to avoid
malfunction by undesirable current.
Common terminal for the 24 VDC power supply (terminal PC).
Isolated from terminal 5.
Common terminal for SX1 and SX2.
Can be used as a 24 VDC 0.1 A power supply.
Common terminal for SY1 and SY2.
FR-E800-SCE
SX1 SX2 PC SD SY1 SC1
10
A
*1
Ferrule part No.
Crimping tool model No.
CRIMPFOX 6
page
19.)
page
21.)
2
5
4 SY2 SC2
B
C
*1
Rated specification
Input resistance: 4.7 kΩ,
voltage when contacts are open:
21 to 26 VDC,
current when contacts are short-
circuited: 4 to 6 mADC
Permissible load:
24 VDC (27 VDC at maximum),
0.1 A (The voltage drop is 3.4 V at
maximum while the signal is ON.)
-
-
Power supply voltage range:
22 to 26.5 VDC,
permissible load current: 100 mA
-
2. Installation and Wiring
3
2
3
4
5
6
7
8
9
10
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800-sce

Table of Contents