Mitsubishi Electric 800 Series Instruction Manual page 26

Functional safety, compact, high functionality inverters
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Activating more than one SLS function
The following shows the operation example when the SLS1 function and the SLS2 function are activated (Pr.S005 = "1").
• When multiple SLS command signals are used, corresponding SLS functions are activated by turning OFF the command
signals.
• When Pr.S005 = "1", the frequency command is changed to the smallest valid value after the SLS functions are activated.
NOTE
• For the CC-Link IE TSN safety communication function and CIP Safety, four operation patterns can be activated at the
same time.
• For PROFIsafe, four patterns can be set but cannot be activated at the same time. (Refer to
26
5. Safety Sub-Functions
5.3 SLS function
Output frequency
Pr.S010
Pr.S007
Pr.S015
Pr.S006
Pr.S014
SLS2 command
(SLS2C)
SLS2 output
(SLS2S)
SLS1 command
ON
(SLS1C)
SLS1 output
ON
(SLS1S)
SLS2 speed
monitoring
SLS1 and SLS2
SLS2 speed
speed monitoring
monitoring
Time
ON
ON
page
41.)