Kaba ILCO FDU User Manual page 124

Lodging access control system front desk unit
Table of Contents

Advertisement

Expiry:
Factory default expiry:
Parameters:
Options:
Notes:
Purpose:
Minimum keycard:
Shortcut:
Expiry:
Factory default expiry:
Parameters:
Keycards
From 1 to 2730 nights
365 nights
Type (Section, Floor, Group, Zone or Area)
Level Staff (from 1 to 255)
Staff Common Areas
The Group Sub-master level should be reserved for housekeepers and/or housekeeper
managers, allowing housekeeper managers to use a Group Lockout keycard (see
section 4.10 part C.5 Group Lockout) to prevent the previous guest from returning to a
room after it has been prepared and inspected.
Properties with one or two FDUs may wish to reserve the Area sub-master level for
use with the Back-up Keycard Kit (part # BK-7911).
Enabled Guest Common Areas can be selectively assigned to all Staff keycards. Refer
to Section 4.6.2.2 – Guest Common Areas encoding for staff keycard for details.
To enable and set up Fixed Time Zones that apply to Staff keycards, see Section 3.6
part 7-1 Fixed Time Zones.
A.15 Bellman's Master
Opens every room on the property, except for Restricted Areas or rooms that have
been locked out using the deadbolt or privacy lock, the Salesman's Lockout, a Room
Lockout keycard or a Hotel Lockout keycard. The Bellman's Master keycard operates
at the room and suite levels only. There are no Time Zones with this keycard, because
the expiry should be set to the length of a shift (or less) in the Expiry Menu.
The Bellman's Master is always a duplicate keycard, so that it cannot be cancelled
unintentionally by a more recently encoded keycard if more than one Bellman is on
duty.
If it is necessary to cancel this keycard, use a Bellman's Reset keycard in every lock
in the facility before issuing replacements. If a valid Bellman's Master keycard is
lost, cancel it immediately.
Bellman's Authorization (BA) or General Manager Authorization (GMA)*
Swipe authorized keycard, press 6 and 4.
Selectable, 1 to 24 hours
24 hours
Guest Common Areas**
Kaba Ilco Lodging Access Control System
New/Duplicate
Guest Common Areas
Number of cards
Time Zones
113