2. System description

2.1. Location

This section provides guidelines for selecting and correctly adapting the equipment to a suitable site.

2.1.1. Site

Locate the equipment in a place which is easily accessible for installation and maintenance work
It is strictly forbidden to place objects of any type on the equipment.
The heat sink can reach temperatures of 85 ºC. Do not place heat-sensitive material close to the
inverter.

2.1.2. IP Rating

The Ingecon
μWind Interface models have an IP65 level of protection against the ingress of foreign matter, which
®
means that outdoor installation is possible.
IP65 means that the equipment is fully dust tight and also protected against the impact of water jets in any direction,
as defined for this protection rating in standard IEC60529.
Despite this, excessive humidity may activate the equipment protection system and cause it to shut itself down.
Locate the equipment in a place sheltered from the rain and away from corrosive environments.

2.1.3. Ambient temperature

The Ingecon
μWind Interface models are designed to operate between -20 ºC and 70 ºC.
®

2.1.4. Atmospheric conditions

The surrounding air must be clean, with a relative humidity of not more than 50% at more than 40 ºC. Higher percent-
ages of relative humidity, of up to 95%, are tolerable at temperatures below 30 ºC.
Account should be taken of the fact that, occasionally, moderate condensation may occur as a result of temperature
changes. For this reason, in addition to the equipment's own protection system, the equipment should also be moni-
tored when operating at sites which may not come within the atmospheric conditions described above.

2.1.5. Contamination rating

The equipment has been designed for a grade 3 contamination rating.