5.2

Function

The product is a self-testing, redundant mechatronic system that meets the requirements of the EN
ISO 13849-1+2 and guarantees the pneumatic safety function, safe venting, even in the event of a
fault in the valve, e. g. due to wear or contamination. Another safety function of the product is the pro-
tection against unexpected start-up after EN 1037.
Via the safety-related electrical connection, the product is connected as a slave to the AS-i-Safety at
Work environment without additional devices.
6
1 LED AS-i
2 Status LED
3 Flow control screw for soft start function
4 Pneumatic port 1 (compressed air inlet)
5 Electronic insert
6 Mono-block valve
7 AS-Interface bus connection
8 Pneumatic port 2 (compressed air outlet)
9 Functional earth connection with earthing channel
(pre-assembled)
10 Pneumatic port 3 (exhaust)
Festo — MS6(N)-SV-...-E-ASIS — 2019-05a