Installation; Pneumatic Installation - Festo MS6N-SV E-ASIS Series Assembly Installation Safety Instructions

Soft start/quick exhaust valve
Hide thumbs Also See for MS6N-SV E-ASIS Series:
Table of Contents

Advertisement

Installation

Fig. 6 Assembly
1. Slide the cover cap MS6-END 1 upwards and remove it.
2. Insert a seal 2 between the individual devices (module connector MS6-MV in scope of delivery).
3. Place module connector 2 in the slots of the individual devices.
4. Fasten the module connector with two screws (product scope of delivery). Tightening torque: max-
imum1.2 Nm.
7
Installation
7.1

Pneumatic installation

Port 1 and 2
If using screw connectors:
Note the screw-in depth of the connector thread: 10 mm.
Make sure that the compressed air lines are connected correctly.
Screw the connectors into the pneumatic connections using a suitable sealing material.
Port 3 (thread size G1 or NPT1)
Exhausting a system using the product results in high noise levels.
Recommendation: use silencer è www.festo.com/catalogue.
Screw the silencer into pneumatic port 3.
Make sure exhaust has no obstacles: do not block silencer or port 3.
For the product, an adapter (from thread size NPT1 to G1) must also be mounted between the silencer
and the product.
Festo — MS6(N)-SV-...-E-ASIS — 2019-05a