Festo MS6N-SV E-ASIS Series Assembly Installation Safety Instructions page 15

Soft start/quick exhaust valve
Hide thumbs Also See for MS6N-SV E-ASIS Series:
Table of Contents

Advertisement

Installation
Data format of diagnostic AS-i object 01 (16 bits)
15
14
13
12
Meaning
0
Pneumatic error: minimum operating pressure not reached (p1 
1
Pneumatic error: maximum operating pressure exceeded (p1 
2
Self-test:
0 = not ready for operation
1 = ready for operation
3
Internal error. Leads to shutdown and lockout
4
Overrun tmin (1/month)
5
Status AUX1, e. g. AS-i communication error
6
Status AUX2
 12
Unassigned
...
13 
 15
Internal valve diagnostics
...
Tab. 9 Data format of diagnostic AS-i object 01
Assigning the AS-i address
Recommendation: use the addressing device ASI-PRG-ADR with connecting cable KASI-ADR from
Festo. The addressing device scans the slave connected to the addressing device.
Addressing for safety-related slave:
1. Insert the AS-i configuration plug CACC-CP-AS into the M12 bushing.
Ä The mode switch changes from run to prog.
2. Assign the desired address to the slave with an addressing device or with the AS-i master. Per-
missible address range 1 ... 31. Factory setting: address #0.
3. Check the address with the addressing device or AS-i master.
4. Check ID-Code. This must be F
5. Check ID1-Code. This must contain the 10th digit of the safety address.
6. Check ID2-Code. This must contain the 1st digit of the safety address.
7. Check IO-Code. This one must be 7.
8. If the verification of the codes was incorrect, repeat the procedure from step 1.
9. Disconnect the AS-i configuration plugCACC-CP-AS.
Ä The mode switch changes from prog to run.
Addressing for non-safety-related slave:
1. Assign an unused address to each slave.
2. Connect the slave to the AS-Interface-Bus.
Festo — MS6(N)-SV-...-E-ASIS — 2019-05a
11
10
9
8
.
hex
7
6
5
4
3
2
1
0
 p1
3.5 bar)
<
min.)
 p1
10 bar)
<
min.).