Assembly

Specifications on mounting and operating conditions in these operating instructions must be
observed.
For use in higher categories (2 to 4), the requirements of EN ISO 13849, e. g. CCF, must be con-
sidered.
The basic safety principles of EN ISO 13849-2 relating to implementation and operation of the
component must be satisfied. For categories 2 to 4, the proven safety principles must be fulfilled
in accordance with EN ISO 13849-2 for the implementation and operation of the component.
When using this product in machines or systems subject to specific C standards, it must be in
compliance with the requirements specified in the standards.
Before using the product, a risk assessment in accordance with the EC Machinery Directive
2006/42/EG, Appendix I, Paragraph 1 and 1.1.2 is required.
The user is responsible for coordinating all applicable safety regulations and rules with the com-
petent authority and for compliance with regulations and rules.
Failures due to a common cause (Common Cause Failure – CCF)
Common cause failures cause the loss of the safety function, since in this case both channels in a two-
channel system fail simultaneously.
The following measures ensure that common cause failures are avoided:
Compliance with the permissible values for vibration and shock stress
Compliance with the temperature range
Compliance with compressed air quality as specified in the technical data, in particular avoiding
flash rust particles (such as caused by servicing work) as well as compliance with the residual oil
content of max. 0.1 mg/m
tained in the compressor oil)
Compliance with the maximum operating pressure, if necessary with a pressure-relief valve
Clogging of the silencer must be avoided è Fig.4.
6
Assembly
NOTICE!
In order to ensure electromagnetic compatibility in accordance with the EMC Directive, note the follow-
ing:
Ensure a wall clearance of 32 mm, e. g. with the MS6-WPB mounting bracket.
Do not lay cables between the wall and the product.
NOTICE!
Failure of the safety function.
Failure to comply with the minimum distance of 15 mm between the silencer and base can result in
the loss of the safety function.
Observe minimum distance of 15 mm below the silencer è Fig.4.
The free space ensures the exhaust can escape.
Place product as close as possible to the installation site
The product can be mounted in any position