6.5 DIGITAL OUTPUTS menu

This menu is used to assign the digital outputs for the electrical line shaft application signals.
Ipa
Parameter Name
11600
Digital Out 1 Source
11602
Digital Out 2 Source
11604
Digital Out 3 Source
11606
Digital Out 4 Source
12028*
Digit Out 1 Mon
12030*
Digit Out 2 Mon
12032*
Digit Out 3 Mon
12034*
Digit Out 4 Mon
12036*
Status Word Mon
Digital Out n Source
Status Word Mon
Nota!
Electrical shaft application status word is automatically mapped on fieldbuds data 2 of ADV200. Therefore, this data
has to be mapped as following:
IPA 4190 Fieldbus S→M2 ipa = 4194
IPA 4192 Fieldbus S→M2 sys = Mdplc 16
User Guide Electrical Line Shaft for ADV200
User type
Enum
Enum
Enum
Enum
Boolean
Boolean
Boolean
Boolean
Int
This parameter is used to assign the signal flags relating to the electrical line shaft
application to digital output n of the ADV200 (1 ≤ n ≤ 4).
Digital output always active (high).
True
indicates that there are no drive faults.
Drive Healthy
indicates that the motor speed is below the drive zero speed
Zero Speed
threshold.
indicates that the slave is working in electrical line shaft
In Sync
mode capturing the master.
indicates that the slave is capturing the master in electrical
ELS Correction
line shaft mode.
indicates that the slave is engaged in a positioning operation
Move Busy
or that phase correction is underway in electrical line shaft
mode.
indicates that the position error warning threshold has been
Pos Error Warn
exceeded in electrical line shaft mode.
indicates that the position error alarm threshold has been
Pos Error Alrm
exceeded in electrical line shaft mode.
indicates that the slave has completed the zero search
Pos Zero Found
procedure successfully.
indicates that the slave has completed a positioning
In Position
operation.
Electrical line shaft application status word monitor. Single bits coding is set as
follows:
Bit 0 ELS Move mon
Bit 1 ELS Engage mon
Bit 2 Home Sensor mon
Bit 3 In Sync mon
Bit 4 Correction mon
Bit 5 Move Busy mon
Bit 6 Home Sensor mon
Bit 7 Home Busy mon
Bit 8 Error Warning mon
Bit 9 Error Alarm mon
Bit 10 Home Complete mon
Bit 11 In Position mon
____________________ _
Target type
Unit
Default
Int
Drive Healthy
Int
Zero Speed
Int
In Sync
Int
Move Busy
Boolean
Off
Boolean
Off
Boolean
Off
Boolean
Off
Int
-
Min
Max
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Page 27 of 32