Digital Inputs Menu - gefran ADV200 User Manual

Electrical line shaft application
Table of Contents

Advertisement

6.4 DIGITAL INPUTS menu

This menu is used to assign the digital commands for the electrical line shaft application functions.
Ipa
Parameter Name
11500
Move Trigger Source
11502
Jog Input Source
11504
ELS Engage Source
11506
Digital Move Trigger
11508
Digital Jog Trigger
11510
Digital ELS Engage
12006*
Move Mon
12008*
Jog Mon
12010*
ELS Engage Mon
12038*
Command Word Mon
Move Trigger Source
Jog Input Source
ELS Engage Source
Digital Move Trigger
Digital Jog Trigger
Digital ELS Engage
Move Mon
Jog Mon
ELS Engage Mon
Command Word Mon
User Guide Electrical Line Shaft for ADV200
User type
Enum
Enum
Enum
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Int
This parameter is used to select the source for the digital command to launch a
positioning operation.
This parameter is used to select the source for the jog digital command.
This parameter is used to select the source for the digital command to capture the
master in electrical line shaft mode.
Local setting for the digital command to launch a positioning operation.
Local setting for the digital command to launch jog operation.
Local setting for the digital command to capture the master in electrical line shaft
mode.
Monitor flag active during positioning or phase correction in electrical line shaft
mode.
Monitor flag active during jog operations.
Monitor flag active when the slave is capturing the master in electrical line shaft
mode.
Electrical line shaft application control word monitor. This contains the commands
defined in the DIGITAL INPUTS menu, in the same order and starting from the
least significant bit.
____________________ _
Target type
Unit
Default
Int
-
DigIn1
Int
-
DigIn2
Int
-
DigIn3
Boolean
-
Off
Boolean
-
Off
Boolean
-
Off
Boolean
-
Off
Boolean
-
Off
Boolean
-
Off
Int
-
-
Min
Max
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Page 26 of 32