PIAGGIO Beverly Tourer 300 i.e. Service Station Manual page 103

Hide thumbs Also See for Beverly Tourer 300 i.e.:
Table of Contents

Advertisement

Beverly Tourer 300 i.e.
g - The activation cycle of the new battery lasts for
30 minutes after the ignition of the recharge LED
has taken place
h - Disconnect the clamps from the battery and
check the voltage, if voltages are detected of less
than 12.8 V, proceed with a new recharge of the
battery starting from point c of the recharge pro-
cedure of the new battery, otherwise go to point i
i - The battery is now completely activated, disconnect the battery charger from the fuel supply grid,
disconnect the clamps from the battery and proceed to fitting the battery on the vehicle.
Connectors
INSTRUMENT PANEL CONNECTOR «A»
1. Left turn indicator warning light (Pink)
2. Immobilizer (Red-Green)
3. Battery-powered (Red-Black)
4. Coolant temperature sensor (Green-Yellow)
5. Not connected
6. Fuel level transmitter (White-Green)
7. Right turn indicator warning light (White-Blue)
8. Low fuel warning light (Grey-Black)
Electrical system
ELE SYS - 103

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading