PLCALIB.EXE (Touch Panel Data Calibration)

By touching the specified position (upper left-hand corner or lower right-hand cor-
ner) on the panel, the difference between the screen's logical value and its measured
value is corrected. Furthermore, it is possible to create files with data based on cali-
bration results obtained here, to be used with the PLATPH.EXE application (Touch
Panel Handler).
Start-up
PLCALIB [Parameter]
∗ Parameter
-a<n>
-q<n>
-c <path name> Specifies the data file containing the calibrated value obtained from
the PLCALIB.EXE application (touch panel data calibration).
Operation
6-12
[↵]
Specifies the I/O base address of the touch panel's SIO port.
Hexadecimal, Default: 2e8 (COM4)
n=
Specifies the interrupt level (IRQ) of the touch panel's SIO port.
When defaulted to, the PLATPH.CAL of the current directory is specified.
∗ Example platph -a2e8 -q10 -cc:\platph.cal
Analog Touch Panel Calibration PLCALIB.EXE Version X.XX
Copyright(c) 199X Digital Electronics Corporation
Calibration Mode
Touch upper left and lower right cornner of the screen.
[Enter]
: Go to test mode.
[Esc]
: Terminate program.
Upper left
Lower right
(0000,0000) (0000,0000)
3f8
(COM1)
n
2f8
(COM2)
3e8
(COM3)
2e8
(COM4)
Default: 10 (COM4)
n=
4
(COM1)
3
(COM2)
11
(COM3)
10
(COM4)
Normally, only "platph" is needed.
When the PLCALIB.EXE application
is opened up, the message shown at
the left will appear on the screen, and
two points will light up, in both the
upper left-hand and lower right-hand
corners.
Bundled Software
PL-5700 Series User's Manual