Bundled Software
Functions available in PL-386 Compatibility Mode
The following data details the functions available in the PL-386 compatibility mode
(when the user's PL-386 application is used without further conversion, updating or
formatting).
INT 59h Function List
Func tion code
0000h
0100h
0101h
0102h
0300h
0400h
0401h
0402h
0500h
0000h
Same as 0200h (Input buffer clear)
Input
Output
0100h
Returns coordinates of the area/position touched. Waits until input is made.
Input
Output
0101h
Returns coordinates of the area/position touched. Immediately restored after input is
made.
Input
Output
PL-5700 Series User's Manual
Touch panel initialization
Touch panel input (unres tricted wait)
Touch panel input (? ? ? a uto restore? ? ? )
Touch panel non-des tructive input
Coordinate code regis ter
Coordinate code input (unres tricted wait)
Coordinate code input (? ? ? a uto restore? ? ? )
Coordinate code non-des tructive input
Touch panel s tatus detection
Touch panel initialization
AX = 0000h
AH = 0: Successfully completed
Touch panel input (unrestricted wait)
AX = 0100h
AH = 0: Successfully completed
BH = Y coordinate range in PL-386 compatibility mode (0 - 26)
BL = X coordinate range in PL-386 compatibility mode (0 - 30)
CX = Number of valid data sets in touch panel input buffers
Touch panel input (immediate restore)
AX = 0101h
AH = 0: Input on ("1" when input is off)
BH = Y coordinate range in PL-386 compatibility mode (0 - 26)
BL = X coordinate range in PL-386 compatibility mode (0 - 30)
CX = Number of valid data sets in touch panel input buffers
Des cription