3. Turn the vertical arm clockwise to the maximum
position.
4. Adjust the ball socket on the cable until it is aligned
with the ball on the lever arm.
5. Turn the ball socket counterclockwise 2 turns.
6. Assemble the ball joint.
7. Attach the lock spring of the ball joint.
8. Tighten the locknut for the ball socket on the cable.
B
A
9. Examine the protective cover for damage. Replace a
damaged cover with a new one.
10. If more adjustment is necessary, adjust the cable
with the cable adjuster adjacent to the hydraulic
pump. Loosen the locknuts (A) and adjust the play
with the adjustment screw (B). Make sure the
hydraulic pump does not touch its bottom when the
pedals are fully pushed.
662 - 001 - 23.10.2018
A
9.5.16 Hydraulic pump
9.5.16.1 To disassemble the hydraulic pump
1. Remove the operator seat. Refer to
and assemble the seat on page 24 .
2. Remove the fuel tank. Refer to
tank on page 44 .
3. Cut the cable ties on the seat switch.
4. Remove the 2 cable retainers.
5. Remove the protection plate below the seat.
6. Remove the 6 screws in the frame section and the
cable retainers below the operator seat.
7. Loosen the 3 screws (A) on the pump belt slide.
A
C