Type 42 Probe Tube and Filter Unit Installation

Before the Installation
Figure 2
Type 42 Probe Tube
(Dimensions in mm)
Type 42 Probe Tube and
Filter Unit Installation
26
CAUTION!
The weight of the probe tube with filter unit amounts to approx. 28–32 kg! Two
persons are needed for transportation and mounting!
Observe the "Piping Plan" in the drawings set.
Make sure that the wall tube is installed at the extraction point (see page 15).
160
Step
Action
1
Insert the probe tube in the wall tube and screw the probe tube flange to
the wall tube flange. Use the green seal from the accessories pack to seal
the space between the flanges.
2
Screw the filter unit to the flange of the probe tube. Use the green seal
from the accessories pack to seal the space between the flanges of probe
tube and filter unit.
3
Mount the heating sleeve on the filter unit.
4
If applicable, install the compressed-air hoses between the filter unit and
the back-purging unit (see page 39).
ACX Analyzer System Commissioning Instruction
1000/1500/2000 mm
CI/ACX-EN Rev. D