2.6 Block search Type 5 SERUPRO
Valid REPOS offset
When the SERUPRO operation is complete, the user can read out the REPOS offset via the
axis/spindle VDI signal (NCK→PLC):
DB31, ... DBX70.0 (REPOS offset).
The effects of this signal on the relevant axis are as follows:
Value 0:
Value 1:
Range of validity
The interface signal:
DB31, ... DBX70.0 (REPOS offset)
is supplied at the end of the SERUPRO operation.
The REPOS offset is invalidated at the start of a SERUPRO ASUB or the automatic ASUB
start.
Updating the REPOS offset within the scope
Between the SERUPRO end and SERUPRO start, the axis can be moved in JOG mode with
a mode change.
The user applies the REPOS offset manually with JOG, in order to set the IS
DB31, ... DBX70.0 (REPOS offset) to the value 0.
In the scope, the axis can also be moved via FC18, where the IS
DB31, ... DBX70.0 (REPOS offset) is constantly updated.
Displaying the range of validity
The range of validity of the REPOS offset is indicated with interface signal:
DB31, ... DBX70.1 (REPOS offset valid)
It is indicated whether the REPOS offset calculation was valid or invalid:
Value 0:
Value 1:
REPOS offset after an axis replacement
With the group signal:
DB21, ... DBX319.5 (Repos DEFERRAL Chan)
can be used to determine whether a valid REPOS offset has taken place:
Value 0:
Value 1:
68
No REPOS offset is applied.
REPOS offset is applied.
The REPOS offset of this axis is calculated correctly.
The REPOS offset of this axis cannot be calculated, as the REPOS has not
yet occurred, e.g., it is at the end of the ASUB, or no REPOS is active.
All axes currently controlled by this channel have either no REPOS offset or
their REPOS offsets are invalid.
Miscellaneous.
Basic logic functions: Mode group, channel, program operation, reset response (K1)