Example:
Programming
CPDEF=(X2)
Boundary conditions
● The maximum number of coupling modules is limited (see Section "Requirements").
● The application of CPDEF to an already created coupling module is possible and will not
result in an alarm being generated.
14.5.3.2
Delete coupling module (CPDEL)
A coupling module created with CPDEF can be deleted with CPDEL.
Programming
Syntax:
Designation:
Functionality:
Following axis/
spindle:
Example:
Programming
CPDEL=(X2)
Axes and spindles
Function Manual, 06/2019, A5E47437747B AA
Range of values: All defined axis and spindle names in the channel
Comment
; A coupling module is created with axis X2 as following
axis.
CPDEL= (<following axis/spindle>)
Coupling Delete
Deletion of a coupling module. All leading axis modules are deleted with
the coupling module and reserved memory is released.
Type:
AXIS
Range of values: All defined axis and spindle names in the channel
Comment
; Deletion of the coupling module with following axis X2.
M3: Coupled axes
14.5 Generic coupling
501