Electrical system
Applies to RBH 180, and RB 150 1996 and 1997 models
The engine does not
stop when the operator
rises from the seat.
Does the engine stop
when the ignition is
switched off?
Yes
Adjust or replace
microswitch S7 under the
operator's seat.
Applies to RBH 180, and RB 150 1996 and 1997 models
The battery becomes
discharged too quickly.
Is specific gravity the
same in all cells of the
battery?
Yes
Does the generator
charge?
Yes
Replace the ignition
switch S9.
TROUBLE SHOOTING
Replace relay K2 (the
lower one).
No
Replace the battery (6).
No
Replace the rectifier, fitted
on the right side of the
No
engine.