gefran AFE200 Series Instruction Manual page 175

Active front end regenerative power supply unit
Table of Contents

Advertisement

LEDS Colour
PHASE
H7
Red
U
PHASE
H8
Red
V
PHASE
H9
Red
W
H10
Red
It lights up to indicate a power rectifier heat sink overtemperature
H11
Red
It lights up to indicate overtemperature of the air inside the drive
H12
Red
IGBT U
H13
Red
IGBT V
H14
Red
IGBT W
It lights up in case of overtemperature of one of the IGBT devices.
The signal temperature relating to the hotter of the master and slave IGBT devices
is sent to the regulation card.
A temperature signal is also sent automatically to the regulation card in case
of minimum temperature, which could occur in the event of a fault in one of the
H15
Red
temperature reading circuits.
The loss of one of the temperature signals is indicated by LED H15, with the code
indicated by the number of flashes (*): the sequence of flashes to indicate the
faulty PHASE or SLAVE has a 3Hz frequency and is repeated cyclically every 5
seconds.
It lights up on the INT-P-ADV MASTER card to indicate that the drive's total current
(master + slave) has exceeded the overcurrent value for the size of drive, whereas
H18
Red
it lights up on the INT-P-ADV SLAVE card to indicate that the SLAVE current has
only exceeded the overcurrent value of the SLAVE.
H19
Red
It lights up to indicate a fault on the DC-BUS power supply regulation card
They light up to indicate a short circuit between the output phases
They light up to indicate loss of the feedback signal relating to the mo-
ment the IGBT devices are switched on. The signal is used for hardware
dead time compensation
(*) Led H15 code indicated by number of flashes
PHASE U
PHASE V
PHASE W
SLAVE 1
SLAVE 2
SLAVE 3
SLAVE 4
AFE200 • Instruction Manual
FUNCTION
ALARM
Normal
functioning
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
NO. FLASHES
1
2
3
4
5
6
7
175