gefran AFE200 Series Instruction Manual page 133

Active front end regenerative power supply unit
Table of Contents

Advertisement

This signal is activated when the alarm configured in parameter 4704 alarm dig sel 3
is active.
Menu
PAR
Description
-
4714
Alm dig out mon 4
This signal is activated when the alarm configured in parameter 4706 alarm dig sel 4
is active.
Menu
PAR
Description
-
4770
First alarm
This parameter displays the first alarm to be activated.
0
No alarm
1
Overvoltage
2
Undervoltage
3
Ground fault
4
Overcurrent
5
Desaturation
6
MultiUndervolt
7
MultiOvercurr
8
MultiDesat
9
Heatsink OT
10
HeatsinkS OTUT
11
Intakeair OT
12
Motor OT
13
Drive overload
14
Motor overload
15
Bres overload
16
Phaseloss
17
Opt Bus fault
18
Opt 1 IO fault
19
Opt 2 IO fault
20
Opt Enc fault
21
External fault
22
Speed fbk loss
23
Overspeed
24
Speed ref loss
25
Emg stop alarm
26
Power down
27
Not Used1
28
Not Used2
29
Not Used3
30
Not Used4
31
Not Used5
32
Not Used6
33
Plc1 fault
34
Plc2 fault
35
Plc3 fault
36
Plc4 fault
37
Plc5 fault
38
Plc6 fault
39
Plc7 fault
40
Plc8 fault
Menu
PAR
Description
-
4780
Alarm PLC
This parameter displays the state of the alarms generated by the application written
UM
Type
FB BIT
BIT
16BIT
UM
Type
FB BIT
UINT32
16BIT
UM
Type
FB BIT
UINT16
AFE200 • Instruction Manual
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Max
Acc
1
ER
Max
Acc
0
ERW
Max
Acc
0
ER
133