Step 2: Identify The Model For Installation - YASKAWA iQpump Micro Quick Start Manual

Ac drive compact intelligent pump controller quick start procedure
Hide thumbs Also See for iQpump Micro:
Table of Contents

Advertisement

iQpump Micro
Quick Start Procedure
STEP
Identify the Model for Installation
2
Safety Symbols in
this Document
WARNING!
Read and understand
users manual before
using this equipment.
Failure to follow users
instructions may result
in serious injury or
death.
WARNING!
Hazardous Voltage.
Contact may cause
electric shock or burn.
Turn-off and lock-out
system and facility
power before servicing.
WARNING!
Stay Clear- Equipment
starts automatically.
Clear all personnel
from equipment, install
shields or guards, locate
and verify emergency
SHUT-OFF is functional.
Failure to comply may
result in serious injury to
personnel.
WARNING!
Improper Operation
Sequence. DO NOT
RUN THE MOTOR.
Failure to comply may
result in serious injury to
personnel.
WARNING!
Do not operate
equipment with covers
or guards removed.
Install or replace cover
and/or guards before
operation. Failure to
comply may result
in serious injury to
personnel.
YASKAWA TOEP YAIQPM 01A iQpump Micro Quick Start Procedure
This Quick Start Procedure serves as general guide to help install, confi gure and perform test run operation.
Refer to the iQpump Micro User Manual No. TOEP YAIQPM 03 for complete instructions to confi gure this
product for each specifi c installation site.
2.1 Verify the correct model and ratings.
Follow this procedure for each iQpumpMicro and motor combination.
a.
Locate the nameplate and your order information.
b.
Verify the Model No: (E) matches the line item(s) on your order, to confi rm receipt of the correct
model.
c.
Locate the nameplate of motor that will be connected.
d.
Confi rm the motor nameplate Amperage, Voltage, and Frequency (Hz) are within the Output
specifi cations (B) shown on the iQpump Micro nameplate.
2.2 Verify main power source is adequate by reviewing the Input
specifi cations (A) shown on the iQpump Micro nameplate.
Output Power
Rating
Input Power
Rating
Output Power
Rating
Weight
Serial
Number
UL File
Number
CIMR-PW
MODEL
:
MAX APPLI. MOTOR : 0.75kW / 0.4kW
INPUT
: AC3PH 200-240V 50 / 60Hz 2.7A / 1.4A
OUTPUT
: AC3PH 0-240V 0-400Hz 1.2A / 0.8A
MASS
: 0.6 kg
O / N
:
S / N
:
FILE NO
: E131457
IP20
YASKAWA ELECTRIC CORPORATION
2-1 Kurosaki-shiroishi, Yahatanishi-Ku, Kitakyushu 806-0004 Japan
REV : A
Output
Amps
IND.CONT.EQ.
7J48
Software
Version
PASS
MADE IN JAPAN
Page 4
of 31

Hide quick links: