YASKAWA iQpump Micro Quick Start Manual page 14

Ac drive compact intelligent pump controller quick start procedure
Hide thumbs Also See for iQpump Micro:
Table of Contents

Advertisement

iQpump Micro
Quick Start Procedure
STEP
Install the 24 V Transducer Power Supply (continued)
5
5.17 Connect wiring from customer-supplied transducer to 24V Power Supply.
Refer to Figure 1.6 Transducer (2-Wire) connection or Figure 1.7 Transducer (3-Wire) connection based on the application.
Figure 1.6
Example:
Customer supplied
pressure transducer
feedback device
(2-Wire)
N/C
4
SIG
1
3
V+
Output
2
N/C
Note: Transducer wire colors and numbering may vary depending on feedback device used, consult feedback device
manual.
Figure 1.7
Note: Set DIP switch S1 located on drive to V position for use with 0 to 10V transducer.
N/C
4
V+
1
3
Com
2
Output
Note: Refer to the iQpump Micro User Manual, (No. TOEPYAIQPM03) to program the iQpump Micro drive for network communication if
required.
YASKAWA TOEP YAIQPM 01A iQpump Micro Quick Start Procedure
(2-Wire) 4 to 20 mA Transducer
24V Power Supply
CN1
Terminal
Block
24V Power Supply
24V
Transducer
AC
Signal 4-20 mA
(typical)
A2
Shield
FE
Internal Circuit
(3-Wire) 0 to 10 V Transducer
24V Power Supply
CN1
Terminal
Block
24V Power Supply
24V
Supply Common
AC
Transducer
Signal 0-10 Vdc
A2
(typical)
Shield
FE
Internal Circuit
iQpump Micro Drive
iQpump Micro Drive
I/O Terminals
TB1-2
P1
TB1-1
P2
PC
TB1-3
A1
J2
A2
V+
AC
AM
AC
TB2
MP
FE
EG
Functional Earth Cable
(Earth
(Blue)
Ground)
iQpump Micro Drive
iQpump Micro Drive
I/O Terminals
TB1-2
P1
TB1-1
P2
PC
TB1-3
A1
J2
A2
V+
AC
AM
AC
TB2
MP
FE
EG
Functional Earth Cable
(Earth
(Blue)
Ground)
Setting DIP Switch S1 for
Terminal A2 Signal Type Selection
Page 14