MASTER FEED SECTION
6.7.5 MASTER VACUUM FAN POSITIONING
PURPOSE: To ensure that the master vacuum fans are installed the correct way
around. If they are installed the wrong way around, there will be no
suction in the master buffer duct, resulting in master jams.
PROCEDURE:
When installing the master vacuum fan, position the cable as shown in the
diagram.
[A]
6-38
C229R103.WMF