MASTER FEED SECTION

6.7.10 MASTER FEED MYLAR POSITIONING

NG
OK
Cutter Unit
After the tension roller
NG
OK
Buffer Duct Entrance Plate
Before the Master Feed Control Roller
PURPOSE: These strips of mylar are easily put in the wrong position. Take care
to set these properly to avoid master jams.
PROCEDURE:
When replacing or removing the thermal head, the cutter unit, the master duct, or
the guide plate of the lower master feed control roller, install the lower tension roller
or lower master feed control roller as shown in the illustration.
C229R114.WMF
C229R112.WMF
6-44
NG
OK
Thermal Head Base
Before the tension roller
NG
OK
Lower Master Feed Control Roller
Exit Guide Plate
1 July, 1998
C229R115.WMF
C229R113.WMF