INSTALLATION PROCEDURE
CAUTION
Unplug the main body power cord before starting the following procedure.
When installing the DF, use the DF tool [A] or a standard screwdriver.
ADF installation
1. Unplug the document feeder. Then, remove the shipping tape.
2. Remove the left scale [B] (2 screws).
3. Place the DF exposure glass [C] on the glass holder.
4. Peel off the backing [D] of the double side tape attached to the rear side of the
scale guide [E], then install the scale guide (2 screws).
5. Attach the original size decal [F] to the scale guide.
NOTE: Place the decal at the rear edge, and the left side flush with the scale
paper guide [E], as shown.
6. Install the stud screws [G].
[A]
A628I500.WMF
[B]
[D]
[C]
[E]
A628I502.WMF
3-14
1 July, 1998
A628I501.WMF
[F]
[G