Chapter 4

MXIbus Trigger Configuration Register

VXIbus Address:
Attributes:
15
14
TRIG7EN
TRIG6EN
7
6
TRIG7DIR TRIG6DIR TRIG5DIR TRIG4DIR TRIG3DIR TRIG2DIR TRIG1DIR TRIG0DIR
This register maps the VXIbus TTL Trigger lines to and from the Trigger In and Trigger Out
SMB connectors on the front panel of the VXI-MXI. These bits are cleared on a hard reset.
Bit
Mnemonic
15-8r/w
TRIG[7-0]EN
7-0r/w
TRIG[7-0]DIR
© National Instruments Corporation
Base Address + 2E (hex)
Read/Write
13
12
TRIG5EN
TRIG4EN
5
4
Description
Trigger Enable Bits
Setting these bits individually enable the corresponding VXIbus
TTL trigger lines to be mapped to the Trigger Out SMB connector
or from the Trigger In SMB connector on the front panel as
specified by the corresponding TRIGxDIR bit. Clearing these bits
disables the mapping of the trigger lines to the front panel SMB
connectors.
Trigger Direction Bits
If the TRIGxEN bit is clear, this bit has no meaning. If TRIGxEN
is set, this bit controls the routing of TTL trigger lines 7 to 0.
If this bit is set, TTL trigger lines 7 to 0 are driven by the signal
received on the front panel Trigger In SMB connector. If this bit is
clear, TTL trigger lines 7 to 0 are driven out of the mainframe
through the Trigger Out SMB on the front panel. This bit is
cleared on a hard reset.
TRIGxEN
0
1
11
10
TRIG3EN
TRIG2EN
3
2
TRIGxDIR
X
Disabled
TTL TRIG X drives TRIG OUT
0
SMB
1
TRIG IN SMB drives TTL TRIG
X
4-49
Register Descriptions
9
8
TRIG1EN
TRIG0EN
1
0
Routing
VXI-MXI User Manual
R/W
R/W