National Instruments VXI-MXI User Manual page 78

Table of Contents

Advertisement

Register Descriptions
The A24 Window Map Register has the following format when the CMODE bit is set:
15
14
A24HIGH7 A24HIGH6 A24HIGH5 A24HIGH4 A24HIGH3 A24HIGH2 A24HIGH1 A24HIGH0
7
6
A24LOW6 A24LOW5 A24LOW4 A24LOW3 A24LOW2 A24LOW1 A24LOW0
A24LOW7
Bit
Mnemonic
15-8r/w
A24HIGH[7-0]
7-0r/w
A24LOW[7-0]
This register defines the range of MXIbus A24 addresses that map into the VXIbus where that
range is:
The VXIbus A24 addresses mapped out of the VXI-MXI are the inverse of this range, that is,
MXIbus A24 addresses greater than or equal to the A24HIGH value or less than the A24LOW
value.
To map a consecutive range of VXIbus A24 addresses out of the VXI-MXI, the lower bound of
the range must be placed in the A24HIGH field and the upper bound in the A24LOW field. In
this case the range of VXIbus A24 addresses mapped out of the VXI-MXI is:
The MXIbus A24 addresses mapped into the VXIbus are the inverse of this range, that is,
VXIbus A24 addresses greater than or equal to the A24LOW value or less than the A24HIGH
value.
The window is disabled whenever A24HIGH = A24LOW = 0. All VXIbus A24 addresses are
mapped out to the MXIbus when:
All MXIbus A24 addresses are mapped into the VXIbus when:
VXI-MXI User Manual
13
12
5
4
Description
A24 Window Upper Bound
These bits define the upper limit of the range of MXIbus A24
addresses that map into the VXIbus.
A24 Window Lower Bound
These bits define the lower limit of the range of MXIbus A24
addresses that map into the VXIbus.
A24HIGH > range A24LOW
A24LOW > range A24HIGH
FF (hex) (A24HIGH = A24LOW) 80 (hex)
7F (hex) (A24HIGH = A24LOW) > 0
4-20
11
10
3
2
© National Instruments Corporation
Chapter 4
9
8
R/W
1
0
R/W