Interrupt Status/Control Register - National Instruments VXI-MXI User Manual

Table of Contents

Advertisement

Chapter 4

Interrupt Status/Control Register

VXIbus Address:
Attributes:
15
14
LINT3
LINT2
LINT2
LINT3
7
6
SYSFAILINT
IRQ7
0
DIRQ7
This register is used to configure local interrupts, drive the VMEbus IRQ lines individually, and
reflect the status of the VMEbus IRQ lines. The upper byte (bits 15 through 8) of this register is
cleared on a hard reset. The lower byte (bits 7 through 0) is cleared on hard and soft resets.
Bit
Mnemonic
15-13r/w LINT[3-1]
© National Instruments Corporation
Base Address + 2A (hex)
Read/Write
13
12
LINT1
ACFAILINT
LINT1
0
5
4
IRQ6
IRQ5
DIRQ6
DIRQ5
Description
Local Interrupt Line Bits
These bits select the VMEbus interrupt request line onto which the
local VXI-MXI interrupts are routed. The local interrupts are
BKOFF, TRIGINT, ACFAIL, and SYSFAIL.
LINT3 LINT2 LINT1
0
0
0
0
1
1
1
1
11
10
TRIGINT
BKOFF
BKOFFIE TRIGINTIE SYSFAILIE ACFAILIE
3
2
IRQ4
IRQ3
DIRQ3
DIRQ4
VMEbus Interrupt Request Line
0
0
Local Interrupt Disabled
0
1
Interrupt Request Line 1
1
0
Interrupt Request Line 2
1
1
Interrupt Request Line 3
0
0
Interrupt Request Line 4
0
1
Interrupt Request Line 5
1
0
Interrupt Request Line 6
1
1
Interrupt Request Line 7
4-45
Register Descriptions
9
8
R
ACFAIL
SYSFAIL
W
1
0
R
IRQ2
IRQ1
DIRQ2
DIRQ1
W
VXI-MXI User Manual