Mxibus Termination; Figure 3-20. Mxibus System - National Instruments VXI-MXI User Manual

Table of Contents

Advertisement

Configuration and Installation

MXIbus Termination

The MXIbus is a matched impedance bus and requires termination networks at the first and last
device in the MXIbus daisy-chain. These terminations minimize reflections caused by
impedance discontinuities at the ends of the cables. These termination networks are located at
the end device's MXIbus connectors and can be either external self-contained modules or internal
plug-in resistor packages. The VXI-MXI comes with terminating resistors installed. If you
prefer, you can replace them with external resistor packages for easy system reconfiguration.
Figure 3-20 shows an example of a daisy-chained MXIbus system, including terminators.
PC/AT
MXIbus System
62-pin MXIbus Connectors
VXI
Mainframe
The VXI-MXI uses the TERMPWR connection on the MXIbus connector as the power source
for external MXIbus termination networks. TERMPWR is protected by a fuse that limits the
maximum current that can be drawn to 2A. The fuse is soldered on the module and is not user
replaceable.
Note:
TERMPWR is not intended to provide power to any other device.
The VXI-MXI is shipped from the factory with terminating SIP resistor networks installed. If
the VXI-MXI will be the first or last device in the MXIbus daisy-chain and external terminating
VXI-MXI User Manual
MXIbus Cable
Controller
Upstream
Terminator

Figure 3-20. MXIbus System

Downstream
Terminator
3-24
© National Instruments Corporation
Chapter 3
VXI
Mainframe
VXI
Mainframe
VXI
Mainframe