Figure 5-8. Worksheet 2 For Example Vxibus/Mxibus System - National Instruments VXI-MXI User Manual

Table of Contents

Advertisement

Chapter 5
MXIbus Link:
Device:
MXIbus Device A
Number of logical addresses required by device:
Round total number up to the next power of two:
List other MXIbus links to this mainframe:
Number of logical addresses required by additional MXIbus links: +
Total number of logical addresses required by this device:
Round total number up to the next power of two:
Device:
MXIbus Device B
Number of logical addresses required by device:
Round total number up to the next power of two:
List other MXIbus links to this mainframe:
Number of logical addresses required by additional MXIbus links: +
Total number of logical addresses required by this device:
Round total number up to the next power of two:
Device:
VXIbus Mainframe #2
Number of logical addresses required by device:
Round total number up to the next power of two:
List other MXIbus links to this mainframe:
Number of logical addresses required by additional MXIbus links: +
Total number of logical addresses required by this device:
Round total number up to the next power of two:
Device:
VXIbus Mainframe #3
Number of logical addresses required by device:
Round total number up to the next power of two:
List other MXIbus links to this mainframe:
Number of logical addresses required by additional MXIbus links: +
Total number of logical addresses required by this device:
Round total number up to the next power of two:
Device:
Number of logical addresses required by device:
Round total number up to the next power of two:
List other MXIbus links to this mainframe:
Number of logical addresses required by additional MXIbus links: +
Total number of logical addresses required by this device:
Round total number up to the next power of two:
Total Number of Logical Addresses Required:
(Add numbers after the "*")
Round total number up to next power of two:

Figure 5-8. Worksheet 2 for Example VXIbus/MXIbus System

© National Instruments Corporation
MXIbus #1
3
4 (2
0
=
3
2
* 4 (2
)
1
1 (2
0
=
1
*
1 (2
23
32 (2
0
=
23
*
32 (2
6
8 (2
MXIbus #3
32
=
40
*
64 (2
=
*
101
128 (2
5-11
Programming Considerations
Range =
E0
2
)
Size =
8-2 = 6
Range =
E0
Size =
8-2 = 6
Range =
E4
0
)
Size =
8-0 = 8
Range =
E4
0
)
Size =
8-0 = 8
Range =
C0
5
)
Size =
8-5 = 3
Range =
C0
5
)
Size =
8-5 = 3
Range =
80
3
)
Size =
8-3 = 5
Range =
A0
6
)
Size =
8-6 = 2
Range =
Size =
Range =
Size =
Range =
80
7
)
Size =
8-7 = 1