Chapter 3
VMEbus Request Level
The VXI-MXI uses one of the four VMEbus request levels to request use of the VMEbus Data
Transfer Bus (DTB). The VXI-MXI requests use of the DTB whenever an external MXIbus
device attempts a transfer that maps into the VXIbus mainframe.
The VXI-MXI is shipped from the factory configured to use VMEbus request level 3, as required
in the VXIbus specification. Request level 3 is the highest priority request level and request
level 0 is the lowest. You can change the VXI-MXI to use any of the other three request levels
by changing the jumper configuration on the jumper blocks labeled VMEbus Request Level on
the front panel. You may want to change request levels to change the priority of the VXI-MXI
request signal. For more information, refer to the VMEbus specification.
To change the VMEbus request level of the VXI-MXI, rearrange the jumpers on the pin arrays as
shown in Figure 3-6.
© National Instruments Corporation
LOGICAL ADDRESS
SWITCH
OFF
ON
1
Shown at
2
Default setting
3
of Logical Address 1
4
5
6
7
8
a. Switch Setting to Default Setting Logical Address
LOGICAL ADDRESS
SWITCH
OFF
ON
1
Shown at
2
Default setting
3
of Logical Address 1
4
5
6
7
8
b. Switch Set to Logical Address hex C0

Figure 3-5. Logical Address Selection

Push this side down for logic 0
Push this side down for logic 1
Push this side down for logic 0
Push this side down for logic 1
3-7
Configuration and Installation
VXI-MXI User Manual