Emergency Shut-off
All SLA Centers have an Emergency Shut-off button on the front panel of the Control Module/
Bay. The iPro 8000/9000 SLA Center has an additional Emergency Shut-off button inside the
Process Chamber. They are bright red with a yellow background. Pressing either switch cuts off all
electrical power to the system, including the laser. See
Caution
This method of power shut-off is not recommended and should be used only in an
Emergency situation.
To restart the system after an emergency shut-off:
Rotate the Emergency OFF button clockwise to reset it, then press the System Enable.
Control Panel Laser LED
An LED light displays the current status of the laser power availability at the laser power supply.
19
"Safety
www.3dsystems.com
L a s e r S a f e t y
Labels".