Engine Faults

FAULT
The starter
does not run
even when
the main
switch is
turned
The starter is
Engine
running, the
rotation speed
cannot be
increased
The starter is
running, but
the engine
cannot be
started
The engine
runs
irregularly

TROUBLESHOOTING

PROBABLE CAUSE
PTO switch set to ON position
Defective safety switch
Dead battery
Loose cable
Defective switch
Defective starter
Low battery
Poor grounding
Incorrect engine oil viscosity
Air in the fuel system
Clogged fuel filter
No fuel supply
Defective engine
Defective key shutdown unit
Air in the fuel system
Clogged fuel filter
SOLUTION
Set the PTO switch to OFF
position
Have it repaired by an authorized
service
Charge the battery
Check for looseness and
corrosion. Clean, tighten and
apply grease
Have it repaired by an authorized
service
Have it repaired by an authorized
service
Charge the battery
Clean the contact and ground
properly
Replace with engine oil of the
correct viscosity
Bleed the system
Clean or replace the filter
Open the fuel supply
Have it repaired by an authorized
service
Have it repaired by an authorized
service
Bleed the system
Clean or replace the filter
119