Electrical system faults

FAULT
The battery is
not charging
The lights are
not bright
Electrical
enough
System
The light does
not come on
The turn signal
light does not
flash
The work light
does not come
on
124
TROUBLESHOOTING
PROBABLE CAUSE
Blown fuse
Defective power
line
Defective
alternator
Loose or damaged
alternator belt
Battery
malfunction
Low battery
charge level
Poor contact on
power lines
Burnt out light bulb
Blown fuse
Bad contact
Burnt out light bulb
Defective light
interrupter
Bad contact
Burnt out light bulb
Bad contact
SOLUTION
Check the power lines and replace the
defective fuse
Check for loose or missing cable, short
circuit, poor grounding, and repair as
needed
Have it repaired by an authorized service
Adjust the belt preload or replace the
cracked belt
Check that the terminals are not loose or
corroded, or that there is a sufficient
amount of electrolyte and take the
necessary measures
Recharge the battery
Check the grounding, clean and tighten
clamps
Replace the bulb
Check the power lines and replace the
fuse
Check the grounding and clean the
clamps
Replace the bulb
Replace
Check the grounding and clean the
clamps
Replace the bulb
Check the grounding and clean the
clamps

Advertisement