Command
Resetting
In the event of a complete system reset, the passwords convert to the default, which is extron.
NOTE:
Reset all device settings to
factory defaults
IP system reset
Reset all settings except IP
settings
Absolute system reset
IP Configuration
After adjusting any IP setting, you must enter the network reboot command
NOTE:
effect.
24
Set date and time
View date and time
24
Set IP address
X2)
KEY:
= Local date and time
X2!
= IP address
ASCII Command
Response
(Host to Switcher)
(Switcher to Host)
E
}
ZXXX
Zpx
E
}
1ZQQQ
Zpq1
E
}
ZY
Zpy
E
}
ZQQQ
Zpq
EX2)
}
CT
Ipt•
(
X2)
(
= set format)
E
}
X2)]
CT
In verbose modes 2 and 3:
Ipt
EX2!
}
CI
Ipi•
Set format: MM/DD/YY-HH:MM:SS
Displayed format: Ddd, DD Mmm YYYY HH:MM:SS
Format nnn.nnn.nnn.nnn
DTP2 T 204 Switcher • Remote Configuration and Control
]
]
]
]
E
2BOOT
X2)]
X2)
= displayed format)
X2)]
X2!]
Additional Description
Reset product-specific settings to
factory default values. Does not
affect IP settings or user files.
Reset only IP settings to factory
values.
Reset all device settings to
factory defaults except IP
settings (communication is
preserved). This command
is recommended for after a
firmware update.
Reset all device settings to
factory defaults except the
firmware version.
}
for the command to take
X2)
Set date and time
in the
format MM/DD/YY-HH:MM:SS
(month/day/year-hour/
minutes/seconds)
Example: 06/22/17-10:07:14.
In this example, the date is
June 22, 2017, and the time is
10:07 and 14 seconds.
X2)
The unit responds with
in the
displayed format.
NOTE:
When power is cycled
to the unit, the date and time
are reset to factory values.
X2)
Show current date and time
in the displayed format:
Ddd, DD Mmm YYYY HH:MM:SS
X2!
Set IP address
.