TP mode switch — Set this switch to DTP or HDBT according to the receiving device
D
connected to the switcher.
ATTENTION:
Position this switch BEFORE connecting the appropriate device to the DTP
Out connector. Failure to comply can damage the endpoint.
Positionnez le sélecteur AVANT de connecter l'appareil approprié au
connecteur TP. Ne pas respecter cette procédure pourrait endommager le
point de connexion.
DTP mode — By default, the output is configured for DTP mode. It supports
remote powering of the DTP receiver, and transmits digital video and audio
and bidirectional IR control. The DTP2 T 204 transmits signals up to 330 feet
(100 meters) to any Extron device with a DTP output.
NOTE: If the receiving device is in the Extron DTP2 series or Legacy
DTP series, set this switch to DTP (Down position). The output transmits
HDMI digital video with embedded audio, analog audio, RS-232 and IR,
and remote power up to 330 feet (100 meters) to any Extron device with a
DTP 330 input, or 230 feet (70 meters to devices with a DTP 230 input.
If the transmitter and receiver are in the Extron DTP2 series, they
can both be powered by one 12 VDC power supply connected to either
unit.
If the transmitter and receiver are NOT both in the Extron DTP2
series, the transmitter and receiver each requires its own 12 VDC power
supply.
HDBaseT mode — When the input is configured tor HDBaseT mode, remote
power is disabled. The DTP2 T 204 transmits digital video, IR control, and
embedded digital audio up to 330 feet (100 meters) to any third party device with
an HDBaseT output.
NOTE: If the receiving device is HDBaseT enabled receiver, set this
switch to HDBT (Up position). The TP output transmits HDMI digital video
with embedded audio along with RS-232 and IR control up to 330 feet
(100 meters) to any device with an HDBaseT input. The transmitter and
receiver each requires its own 12 VDC power supply.
Over TP RS-232 and IR connectors — (Optional) Connect a serial RS-232 signal, a
E
modulated IR signal, or both to this shared 3.5 mm, 5-pole captive screw connector for
bidirectional RS-232 and IR communication (see
Control
on page 14 to wire this connector).
Wiring for Over TP RS-232 and IR
DTP2 T 204 Switcher • Installation