Extron electronics DTP2 T 204 User Manual page 35

Dtp switching transmitters, four input switcher with integrated dtp2 transmitter
Hide thumbs Also See for DTP2 T 204:
Table of Contents

Advertisement

X!
=
Input number
0 through 4
0 = Deselect (mute) all inputs
For auto-input switching:
X@
=
On and off, or audio mute status
0 = Off, disabled, not selected, undetected, or unmuted
1 = On, enabled, selected, detected, or muted
X#
=
Video mute
0 = Unmute video and sync
1 = Mute video to black screen
2 = Mute video and sync
X%
=
Auto-input switch mode
0 = Disabled — Manual switching (default)
1 = User-defined priority mode — The switcher selects the input to which the user
assigns priority. If no priority is assigned, the switcher selects the active input with the
highest number.
2 = Input memory priority mode — The switcher selects the most recently applied
input, and retains a history of the order in which active inputs are connected to the
unit. If an active input is removed, the switcher switches to the most recently prioritized
input.
X^
=
Video color bit depth mode
0 = Automatically truncate based on output (default)
1 = Force truncation to 8-bit
X&
=
EDID slot number —
1 through 4 = Input slots
5 = Output slot
X*
=
Current EDID information in hexadecimal format (128 or 256 bytes of raw hex data)
X1)
=
Native resolution and refresh rate from selected EDID
Example: 1920x1200@60Hz
X1!
=
Output 5 V mode
0 = Auto — 5 V is enabled only when a source with 5 V is present.
1 = 5 V is always enabled (default).
X1@
=
Input HDCP status
0 = No source detected
1 = Source with HDCP detected
2 = Source without HDCP detected
X1#
=
Output HDCP status
0 = No sink detected
1 = Sink with HDCP detected
2 = Sink without HDCP detected
X1$
=
Output HDCP mode
0 = (Default) Encrypt as required by input.
For HDMI sinks, perform continuous trials.
For DVI sinks, attempt for 10 seconds, then fail.
1 = Always encrypt.
For HDMI sinks, perform continuous trials.
For DVI sinks, attempt for 10 seconds, then fail.
X1%
=
TP mode
0 = DTP mode
1 = HDBaseT mode
X1^
=
Remote power status
0 = Remote power off
1 = DTP2 48 VDC power on
DTP2 T 204 Switcher • Remote Configuration and Control
1
4
through
27

Advertisement

Table of Contents
loading