Connection Box Pn Plus - Siemens SIMATIC HMI Mobile Panel 277 RO Operating Instructions Manual

Hmi device
Table of Contents

Advertisement

Technical specifications
10.2 Specifications
10.2.4

Connection box PN Plus

Weight
Weight without packing
Supply voltage
Rated voltage
Permitted voltage range
Transients, maximum permissible
Time between two transients, minimum
Power consumption connection
box PN without Mobile Panel
Power consumption connection
box PN with Mobile Panel
Enabling button
STOP button
Fuse, internal
Current load PLC-accompanying signals
Recovery time
Note
Recovery time
Wait for approximately one second after you have removed the connecting cable from the
connection box before you plug the connecting cable back into the connection box.
Power failure
It is necessary to remove and replace the connecting cable in the event of power failures
lasting less than a second in order to eliminate possible malfunctions.
134
Approx. 700 g
Typical
Constant current, maximum
Power on current surge I
2
Typical
Constant current, maximum
Power on current surge I
2
Connection voltage
Amperage, max.
Amperage, min.
Connection voltage
Amperage, max.
Amperage, min.
Operating Instructions, 10/2015, A5E36824256-AA
+24 VDC
20.4 V to 28.8 V (–15 %, +20 %)
35 V (500 ms)
50 s
Approx. 100 mA
Approx. 150 mA
t
Approx. 0.5 A
s
2
Approx. 600 mA
Approx. 750 mA
t
Approx. 0.6 A
s
2
24 V DC
400 mA
10 mA
24 V DC
500 mA
10 mA
Electronic
Max. 100 mA
After 1 s
Mobile Panel 277 RO

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents