The steam boiler is comprised of:
A
Safety thermostat (150°C-CSA version
for the north american market only)
B Level probe
C Temperature probe
D 6 bar expansion valve
E
Steam solenoid valve connection fitting
F
Cappuccino maker valve connection fit-
ting
G Vacuum valve
The steam boiler tank contains:
A
2600W heating element
B Fuse 184°C
C Drain plug
D Water inlet connection
E
Hot water solenoid valve (version with
hot water economizer) connection
To replace the fuse placed in the bottom part
of the boiler tank, it's necessary to:
1
Switch off the machine.
2
Unplug the Talento.
4.4
SERVICE MANUAL
Fig. 7
Fig. 8
Fig. 9
Fig. 10
A
B
F
E
D
E
C
B
A
Edition 02 to 12/2013
C
G
D
1