12.5
DATA TRANSFER WITH
USB KEY
1
Insert the USB key in the Talento machine.
Fig. 12
2
Switch off the Talento machine (the display
shows OFF).
3
Push for 5 seconds the button 5 and 10 (the
two last buttons hot water and steam as
standard settings), the display shows:
DISPLAY
CPU
SET - >USB
>
USB - >SET
4
With arrow up and down can you chose the
data transfer, SET
from the machine to the USB stik, or USB
SET to transfer the data from the USB to
the machine. Press ENTER
the data transfer, when the display shows
OK, the data transfer is completed and the
display come back to the first menu.
5
Remove the USB memory stick and press
RESET
to come back in OFF.
12.6
SERVICE MANUAL
<
USB to copy the data
to start
12.6
RESET ABSOLUTE
COUNTER
To reset the absolute counters, start the pro-
gramming in technical mode (second level with
password 1-2-3-4-5 keys), when the display
shows COUNTER or PROG DOSES or SETTING
hold pressed the keys number 5 and 10 for five
seconds,
Fig. 13
1
2
3
4
5
the display shows:
RESET
ABSOLUTE C.
CONFIRM
Hold pressed again keys number 5 and 10 for
Fig. 14
1
2
3
4
5
6
7
8
9
10
6
7
8
9
10
Edition 02 to 12/2013