Nuova Simonelli Talento Service Manual page 133

Hide thumbs Also See for Talento:
Table of Contents

Advertisement

DISPLAY
ALARM BOILER
FILLING
HEATING
TIME
ALARM COFFEE
TEMP
ALARM
STEAM TEMP
ALARM
GROUP TEMP
CLEANING
Edition 02 to 12/2013
SERVICE MANUAL
CAUSA
EFFECT
The heater
The machine will
filling stage
stop. (during first
has exceeded
installation, when
the 2 minutes
the boilers are
maximum time;
empty, this alarm
the probe level
will appear twice)
is uncovered.
The boiler and
The machine
group heating
functions are
stage has
blocked.
exceeded the
20 minutes
maximum time.
The coffee boiler
The machine
temperature
functions are
probe is broken.
blocked.
The steam boiler
The machine
temperature
functions are
probe is broken.
blocked.
The group
The machine
temperature
functions are
probe is broken.
blocked.
One of the set
The machine
cleaning alarms
functions are
programmed
blocked.
has reached
the set value
with WASHING
BLOCK active.
SOLUTION
Switch OFF and ON
the machine. If the
alarm reappears after
the second time of
trying,
pleas
check
the
automatic
level
solenoid
valve
and
clean the level probe
in the steam boiler and
check its connection.
Switch on and off the
machine, and check
the LED lights in the
control board indicating
the heating process.
The led light indicate
which
element
is
continuously powered.
Check the thermo fuse
or heating element and
change if necessary.
Check the connection
of the coffee boiler
temperature probe or
change it.
Check the connection
of the steam boiler
temperature probe or
change it.
Check the connection of
the group temperature
probe or change it.
Operate the washing
cycle.
SEE
PAR.
4.2
5.3
16.2
6.4
4.4
3.4
4.2
16.2
4.2
16.2
3.4
16.2
14.5
11.4.7
11.4.8
11.4.9
11.4.10
13.3