The machine has a ready-connected 3/4 water
supply pipe.
During initial installation, the service engineer
needs to:
1
Fit a filter to the end of the pipe and connect
this to the water mains (Fig. 9).
2
Make sure that the inlet pressure is <4 bar
and if this is not the case, fit a suitable pres-
sure reducer.
3
Insert a clamp (A) to the drainage pipe and
insert the drainage pipe into the relevant fit-
ting, under the machine.
4
Tighten the pipe clamp firmly and connect
the other end to the drainage outlet.
5
To easily insert the drain pipe, remove the
two screws from the drain conveyer and
move up the machine with two cups. Fix
back the two screws after connected the
pipe.