Figure 96: Gtr 8000 Base Radio Modules - Motorola ASTRO 25 GTR 8000 Manual

Base radio
Hide thumbs Also See for ASTRO 25 GTR 8000:
Table of Contents

Advertisement

MN003286A01-E
Chapter 9: GTR 8000 Base Radio FRU Procedures

Figure 96: GTR 8000 Base Radio Modules

NOTICE: The IP address for the device is available through a serial port connection in
Configuration/Service Software (CSS) in the Tools menu.
Prerequisites: Before replacing the transceiver, pull configuration and hardware information from the
transceiver into the Unified Network Configurator (UNC) by performing a "Pull All" procedure from the
UNC. See the "Scheduling the Pull of Device Configurations" section in the Unified Network
Configurator manual.
This step may not be possible if communication is severed between the transceiver and the UNC, or if
the transceiver is within a K core or non-networked site.
Procedure:
1 Wear an electrostatic discharge (ESD) strap and connect its cable to a verified good ground.
CAUTION: Wear the ESD strap throughout this procedure to prevent ESD damage to
any components.
2 Locate the transceiver module being replaced.
3 If the transceiver module is not operational, go to
4 Connect to the transceiver module Ethernet service port using CSS. See
an Ethernet Port Link on page
5 Save the base radio configuration to the service computer/laptop as follows:
a From the menu, select File → Read Configuration From Device.
b At the confirmation screen, click OK.
c When the Progress Monitor screen is complete, click OK.
d From the menu, select File → Save As.
e On the Properties Screen, enter the IP address of the base radio. Click OK.
f
On the Save window, select the directory where you want to save the configuration file, type
a meaningful name for the file (use .cpl as the extension or do not type an extension). Press
E
.
NTER
The base radio configuration is saved to the location indicated. The configuration file is reloaded
later to the replacement transceiver.
6 For a trunked base radio, place the base radio into Service Mode so that the system does not
attribute the loss of channel to a failure:
a From the menu, select Service → Test and Measurement Screen.
The Test and Measurement Screen appears.
b Click Change to Service Mode.
232
step
9.
140.
Connecting Through

Advertisement