Configuring The T2-2R With Duplexer And Triple Relay Option Kit; Connecting Through An Ethernet Port Link - Motorola ASTRO 25 GTR 8000 Manual

Base radio
Hide thumbs Also See for ASTRO 25 GTR 8000:
Table of Contents

Advertisement

f
Disconnect the Ethernet cable from the transceiver module Ethernet service port.
g Repeat for each device in the configuration.
A.3.4

Configuring the T2-2R with Duplexer and Triple Relay Option Kit

Prerequisites: Ensure that all required installation procedures have been performed for the base radio
and receiver and that the devices have been powered up.
When and where to use: This procedure is used to configure a T2-2R with Duplexer and Triple Relay
configuration using the Configuration/Service Software (CSS).
Procedure:
1 If necessary, perform the initial configuration for the base radio and receivers. See
Configuration in CSS on page 134
2 Connect to the Ethernet port on the device. See
page 140
for details.
3 From the menu, select File → Read Configuration From the Device.
4 From the navigation pane, select Hardware Configuration. Set Station Type [R] to Analog
Only.
NOTICE: When configuring GPW 8000 Receivers, the Hardware Platform [R]
parameter is set to GPW 8000 Satellite Receiver. The Antenna Relay [R] parameter is
not configurable for GPW 8000 Receivers.
5 Set Antenna Relay [R] to Enabled.
6 Set Antenna Relay Delay to 80 msec.
NOTICE: The 80 msec antenna rely delay is required to allow sufficient time for all
antenna relays to propagate the transmission signal from the GTR 8000 Base Radio.
This step is not required for GPW 8000 Receivers.
7 From the navigation pane, select WildCard Tables. Click Set to Default to add default
WildCard tables.
8 Click Yes to reset the WildCard Tables to their default structure. The following default WildCard
Tables are created:
NOTICE: WildCard Table numbers are arbitrary and shown for illustration purposes.
Memory size and the number of States and Commands in each table limit the maximum
number of WildCard tables.
Wild-
Descrip-
Card
tion
Table
1
In-cabi-
net RPT
2
Rx In-
hibit
Appendix A: Conventional GTR 8000 Base Radio Option Kits
for details.
Connecting Through an Ethernet Port Link on
States and Condi-
tion
State
Value
Input 6
n/a
Input 7
n/a
Actions
Com-
Value
mand
In-cabi-
n/a
net Re-
peat ON
RX IN-
n/a
HIBIT
MN003286A01-E
Device
Inactions
Com-
Value
mand
In-Cabi-
n/a
net Re-
peat
OFF
RX EN-
n/a
ABLE
307

Advertisement

Table of Contents
loading